首页> 外文会议> >Characterization of an optical multilayer hydrophone for use as broadband ultrasound reference receiver - comparison with PVDF membrane hydrophones
【24h】

Characterization of an optical multilayer hydrophone for use as broadband ultrasound reference receiver - comparison with PVDF membrane hydrophones

机译:用作宽带超声参考接收机的光学多层水听器的特性-与PVDF膜水听器的比较

获取原文

摘要

The performance of an optical multilayer hydrophone for ultrasound detection comprising a thin high-finesse dielectric interference filter structure deposited onto a plane glass plate is experimentally investigated. The characterization given covers the frequency response in the range from 1 to 75 MHz, the sensitivity, the stability and the directional response. The results are compared with typical characteristics of PVDF hydrophones. The optical multilayer hydrophone is well suited for use as a broadband reference receiver for secondary hydrophone calibration, in particular because of the constant response in a wide frequency range. In an application example the complex-valued broadband frequency response of a fiber-optic hydrophone is determined using this reference.
机译:实验研究了用于超声检测的光学多层水听器的性能,该水听器包括沉积在平板玻璃板上的薄型高精细介电干涉滤光片结构。给出的特性涵盖了从1到75 MHz范围内的频率响应,灵敏度,稳定性和方向响应。将结果与PVDF水听器的典型特性进行了比较。光学多层水听器非常适合用作二次水听器校准的宽带参考接收机,特别是因为在宽频率范围内具有恒定的响应。在一个应用示例中,使用此参考来确定光纤水听器的复数值宽带频率响应。