摘要

In our previous paper (1998), we compared model reduction, in both open and closed loops, with closed-loop identification of a low-order model. Both methods were applied to the design of a controller for the secondary circuit of a nuclear pressurized water reactor (PWR), leading to the conclusions that system identification is a viable alternative to model reduction, and that the key feature for a successful control design is not so much the choice between order reduction or identification, but between open-loop and closed-loop techniques. In the present paper, we go further in this study and we compare model reduction with controller reduction for the same PWR system. We show that closed-loop techniques are more powerful than open-loop ones, and that controller reduction gives better results than model reduction when appropriate frequency weighting are chosen.
机译:在我们之前的论文(1998年)中,我们将开环和闭环中的模型归约与低阶模型的闭环识别进行了比较。两种方法都被应用于核压水堆(PWR)二次回路控制器的设计,得出的结论是,系统识别是模型简化的可行替代方案,而成功进行控制设计的关键特征是在阶数减少或识别之间的选择不是太多,而是在开环和闭环技术之间选择。在本文中,我们将进行更深入的研究,并将相同的压水堆系统的模型约简与控制器约简进行比较。我们证明了闭环技术比开环的人更强大,当选择合适的频率加权该控制器还原,得到比减少模型更好的效果。