首页> 外文会议> >ANALYSIS HEAT TRANSFER PERFORMANCE OF R410A FIN-TUBE EVAPORATOR IN AIR CONDITIONER SYSTEM
【24h】

ANALYSIS HEAT TRANSFER PERFORMANCE OF R410A FIN-TUBE EVAPORATOR IN AIR CONDITIONER SYSTEM

机译:R410A翅片蒸发器在空调系统中的传热性能分析

获取原文

摘要

In order to adapt the requirement on environment protection and energy saving for small refrigerating unit, a R410A air-conditioner matching test unit has been set up with the aim to evaluate the system or the part performance. On the basis data of single tube test on convective boiling heat transfer for pure R410A, micro-fin tube is employed to enhance heat transfer in this paper. Evaporator’s heat transfer coefficients and pressure drops were measured form a given area in smooth and micro-fin tubes with O.D. 9.52 mm. With the heat mode of the heat pump test condition, several experiments from the evaporator’s refrigerant side and the air side were carried out to check up the heat exchanger or system performance.
机译:为了适应小型制冷机组对环境保护和节能的要求,已建立了R410A空调配套测试装置,以评估系统或零件的性能。基于纯R410A对流沸腾换热的单管试验数据,本文采用微翅片管增强换热。在O.D的光滑和微翅片管中,在给定区域内测量蒸发器的传热系数和压降。 9.52毫米在热泵测试条件的加热模式下,从蒸发器的制冷剂侧和空气侧进行了一些实验,以检查热交换器或系统的性能。