CLRC Daresbury Laboratory operates the SRS light source, which consists of a linac, booster synchrotron, storage ring and 41 experimental stations. Protection of personnel from radiation and the hazards associated with the accelerators and photon beamlines is ensured through a dedicated personnel safety (PS) system. The design of the PS interlock hardware was produced over 20 years ago, and has been implemented using two generations of technology. The PS system has recently been reviewed due to changes in legislation and in preparation for future accelerator projects. This review included a formal analysis of part of the system using the technique of fault tree analysis to examine likely failure modes and system integrity. The analysis takes into account both hardware and human factors. This paper briefly presents the SRS PS system and discusses the outcome of the recent review and analysis.
机译:CLRC Daresbury实验室操作SRS光源,该光源由直线加速器,助力同步加速器,存储环和41个实验站组成。通过专用的人员安全(PS)系统,确保人员免受辐射以及与加速器和光子束线相关的危害。 PS互锁硬件的设计产生于20多年前,并已使用两代技术实现。由于法规的变化以及为未来加速器项目的准备工作,最近对PS系统进行了审查。这篇综述包括使用故障树分析技术对系统的一部分进行正式分析,以检查可能的故障模式和系统完整性。该分析考虑了硬件和人为因素。本文简要介绍了SRS PS系统,并讨论了近期审查和分析的结果。

著录项