The transient energy function (TEE) and single machine equivalent (SIME) techniques have been used successfully over the years to compute the critical clearing time for faults in the system. Sensitivity of the energy margin has also been used to find critical generators for rescheduling of generation. This procedure involves using trajectory sensitivities explicitly and the computation of the critical energy V/sub cr/ depends on the system parameters. The need to compute V/sub cr/ makes it computationally intensive. In this paper, the authors compute the sensitivity of the energy function to the fault clearing time t/sub cl/ directly. By computing this sensitivity for two values of t/sub cl/, the results can be extrapolated to obtain a good estimate of t/sub cl/. The method is illustrated for a structure-preserving model of a 3-machine, 9-bus power system with nonlinear voltage dependent loads.
机译:多年来,瞬态能量函数(TEE)和单机等效(SIME)技术已成功用于计算系统故障的关键清除时间。能量裕度的敏感性也已被用于寻找重要的发电机以重新安排发电时间。此过程涉及明确使用轨迹灵敏度,并且临界能量V / sub cr /的计算取决于系统参数。计算V / sub cr /的需要使其计算量很大。在本文中,作者直接计算了能量函数对故障清除时间t / sub cl /的敏感度。通过针对t / sub cl /的两个值计算此灵敏度,可以外推结果以获得t / sub cl /的良好估计。该方法针对具有非线性电压相关负载的3机,9总线电力系统的结构保留模型进行了说明。