首页> 外文会议> >The correct method of calculating energy savings to justify adjustable frequency drives on pumps
【24h】

The correct method of calculating energy savings to justify adjustable frequency drives on pumps

机译:计算节能量的正确方法,以证明泵上的变频器是合理的

获取原文

摘要

It is easy to make a bad business decision when using electrical energy savings as a justification to install adjustable frequency drives (AFDs) on pumps. The simple hydraulic formulae and "rules-of-thumb" are easily misapplied and the errors will generally always economically favor the AFD installation. To use energy savings as a justification for an AFD installation, it is necessary to accurately determine these savings over the life of the equipment. These savings are not dependent upon the AFD or motor characteristics but depend upon the characteristics of the process system. This paper is tutorial in nature and shows why AFDs save electricity, gives examples of the common errors that are made in performing the savings calculations, shows how to do these calculations correctly, shows how to mathematically model the process to assist in performing the analysis and shows how to perform the economic calculations to arrive at a rate-of-return on the AFD investment.
机译:使用节电作为在泵上安装变频器(AFD)的理由时,很容易做出错误的业务决策。简单的液压公式和“经验法则”很容易被误用,这些错误通常会在经济上始终有利于AFD安装。要将节能作为安装AFD的理由,有必要在设备的使用寿命内准确确定这些节能量。这些节省不取决于AFD或电机特性,而是取决于过程系统的特性。本文本质上是教程,并说明了AFD为何节省电,给出了执行节余计算时常见错误的示例,说明了如何正确执行这些计算,说明了如何对过程进行数学建模以帮助执行分析和说明如何进行经济计算以得出AFD投资的回报率。