Harmonic reduction in a single-switch, three-phase boost rectifier with high order harmonic injected PWM

机译:具有高阶谐波注入PWM的单开关三相升压整流器的谐波降低

获取原文

摘要

A single-switch three-phase boost rectifier cannot be pushed to high power levels due to high total harmonic distortion (THD). An approach employing high order harmonic injected PWM is proposed to reduce the harmonic content to meet the IEC 555-2 (A) standard for a 5-10 kW power application without significantly increasing the output. The results are verified by a prototype converter operating at 800 V/6 kW with a 3/spl times/220 V input.
机译:由于高总谐波失真(THD),单开关三相升压整流器无法推高功率。提出了一种采用高阶谐波注入PWM的方法来降低谐波含量,以在5-10 kW功率应用中满足IEC 555-2(A)标准,而不会显着增加输出。结果通过一个工作在800 V / 6 kW,输入电压为3 / spl次/ 220 V的原型转换器进行验证。