A moisture probe based upon neutron moderation has been designed, tested and built for measuring the moisture concentration of hazardous waste stored in the underground waste tanks at the DOE Hanford site. The probe is 1 inch in diameter, 24 inches long, and is deployed using a computer controlled winch into a cone penetrometer for in situ moisture measurements. Two thermal neutron detectors in a near-far geometry and a low-intensity /sup 252/Cf source are used in the probe to count thermalized neutrons for determining the moisture content. Several testbeds were constructed and a variety of experiments were performed to determine the optimal detector-source geometry and to rest that the sensor is capable of operating in the expected high temperature and very high gamma-ray fields within the tanks. Several calibration curves of the near-far count rate ratio were determined for tanks contaminated with various levels of neutron absorbing materials. A field-ready probe and a winch deployment system have been delivered for application of this technology to the Hanford Site tank farms.
机译:已经设计,测试和制造了一种基于中子缓和的水分探测器,用于测量DOE Hanford站点地下废物罐中存储的有害废物的水分浓度。该探头的直径为1英寸,长为24英寸,并使用计算机控制的绞盘将其部署到锥形渗透仪中,以进行原位水分测量。在探头中使用两个具有近远几何形状的热中子探测器和一个低强度/ sup 252 / Cf源,以对热中子进行计数以确定水分含量。建造了几个试验台,并进行了各种实验,以确定最佳的探测器源几何形状,并保证传感器能够在储罐内的预期高温和非常高的伽马射线场下工作。确定了受不同水平的中子吸收材料污染的储罐的远近计数率比的几条校准曲线。已交付现场准备就绪的探针和绞车部署系统,以将该技术应用到汉福德工地的油库。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号