首页> 外文会议> >Analytical modeling of advanced reactor passive containment cooling systems to assess wind sensitivity
【24h】

Analytical modeling of advanced reactor passive containment cooling systems to assess wind sensitivity

机译:先进反应堆被动安全壳冷却系统的分析模型,以评估风敏性

获取原文

摘要

Summary form only given. A computer analysis was performed to determine the effects of wind on the Heavy Water Reactor Facility (HWRF) Passive Containment Cooling System (PCCS). The PCCS is designed to remove heat released to the containment following a postulated beyond design basis event. Because the PCCS relies on natural convection and buoyancy-driven flow to remove heat, external wind effects must be evaluated to assure that the system performance is not degraded for any credible wind condition. The TEMPEST code was used to analyze the HWRF PCCS for various wind velocities and directions. A 3-D model for the PCCS and surrounding structures was constructed, and the results of this analysis indicate that the design is essentially wind-neutral, with no appreciable increased or decreased performance for wind speeds of 0-60 ft/s. The results of this analysis will be used to provide pretest predictions for wind tunnel testing scheduled for 1993.
机译:仅提供摘要表格。进行了计算机分析,以确定风对重水反应堆设施(HWRF)被动安全壳冷却系统(PCCS)的影响。 PCCS旨在消除假定超出设计基准的事件后释放到安全壳的热量。由于PCCS依靠自然对流和浮力驱动的气流来散热,因此必须评估外部风影响,以确保在任何可靠的风况下系统性能均不会降低。 TEMPEST代码用于分析HWRF PCCS的各种风速和风向。构造了用于PCCS和周围结构的3-D模型,分析结果表明该设计实质上是风中性的,对于0-60 ft / s的风速,性能没有明显的提高或降低。该分析的结果将用于为定于1993年进行的风洞测试提供预测试预测。