首页> 外文会议> >Control features of the HVDC Gezhouba-Shanghai transmission scheme
【24h】

Control features of the HVDC Gezhouba-Shanghai transmission scheme

机译:葛洲坝—上海高压直流输电方案的控制特性

获取原文

摘要

The HVDC transmission scheme, the first in China, transmits 1200 MW at +or-500 kV from the Gezhouba hydro plant, in Central China to Nan-Qiao near Shanghai over a distance of 1045 km. The authors discuss the operating environment of the interconnected AC systems of Central and East China in terms of frequency and voltage variations. This leads to the establishment of the power regulation and the reactive power requirements of the HVDC transmission terminals. The authors then focus on the control strategies adopted by the HVDC scheme to match these requirements. Reactive power and AC voltage controls using the HVDC converter terminals represent the first application of such techniques in long transmission systems. Step-power modulation functions activated by the HVDC control system are also exercised. The features and functions of such a microprocessor based control scheme are presented in detail. A sample of commissioning field tests demonstrating these control features are also presented.
机译:HVDC输电方案是中国第一个输电方案,以1045 km的距离从中国中部的葛洲坝水电厂向上海附近的南桥输电1200 MW,电压为+或-500 kV。作者从频率和电压变化的角度讨论了华中和华东地区互连的交流系统的运行环境。这导致建立了HVDC传输终端的功率调节和无功功率要求。然后作者将重点放在高压直流输电方案采用的控制策略上,以符合这些要求。使用HVDC转换器端子的无功功率和AC电压控制代表了此类技术在长输电系统中的首次应用。还执行由HVDC控制系统激活的步进功率调制功能。详细介绍了这种基于微处理器的控制方案的特征和功能。还提供了演示这些控制功能的调试现场测试样本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号