首页> 外文会议>World renewable engery congress;WREC 2004 >EFFECT OF GLASS THICKNESS ON THE THERMALPERFORMANCE OF EVACUATED GLAZING
【24h】

EFFECT OF GLASS THICKNESS ON THE THERMALPERFORMANCE OF EVACUATED GLAZING

机译:玻璃厚度对真空玻璃的热性能的影响

获取原文
获取原文并翻译 | 示例

摘要

Flat evacuated glazing consists of two plane glass panes separated by a narrow internalrnevacuated space. Separation of the space is maintained by an array of small support pillarsrntypically 0.32mm diameter and 0.12mm high arranged on a regular square grid with an inter-pillarrnseparation of up to 40mm. A detailed three-dimensional finite volume model (FVM) hasrnbeen employed to determine the variation of thermal performance of an evacuated glazing asrna function of glass pane thickness. It was predicted that for evacuated glazing of dimensionsrnof 0.3m by 0.3m and 0.5m by 0.5m, reducing glass pane thickness gave improved thermalrnperformance. For evacuated glazings with dimensions of 1m by 1m, the opposite wasrnpredicted.
机译:平面真空玻璃窗由两个平面玻璃板组成,玻璃板之间由狭窄的内部真空空间隔开。空间的分隔由直径通常为0.32mm,高度为0.12mm的小支柱组成,这些支柱布置在规则的正方形网格上,支柱间的间距最大为40mm。详细的三维有限体积模型(FVM)已被用来确定玻璃板厚度的真空玻璃窗玻璃功能的热性能变化。据预测,对于尺寸分别为0.3m x 0.3m和0.5m x 0.5m的真空玻璃,减小玻璃板的厚度可提高热性能。对于尺寸为1m x 1m的疏散玻璃,则要进行相反的预测。