Case study on vibration reduction for a condensate vertical pump in the energy plants

机译:电厂凝结水立式泵减振的案例研究

获取原文

摘要

A vertical pump which circulates condensate water or coolant to a reactor in energy plants has been exposed to a severe environment such as a heavy volume of suction and discharge, coupling with electromagnetic and mechanical forces. Vibration phenomena in the vertical pump structure are complicated and unpredictable.In order to find the fundamental cause of high vibration in condensate pump, frequency response and operational deflection shape of the pump are measured and analyzed. Analyzed natural frequency is near the operating speed, and this means that a high vibration is caused by resonance.Correction of vibration which is caused by resonance requires a change in the spring rate or mass of the system to stiffen or weaken the pumps. In this paper, a case study of vibration reduction of the condensate pump has been made with design changes. Results are validated through the test after pump installation. results.
机译:将冷凝水或冷却剂循环到发电厂的反应堆的立式泵已经暴露于恶劣的环境中,例如大量的吸入和排放,以及电磁力和机械力。立式泵结构中的振动现象是复杂且不可预测的。为了找出凝结水泵高振动的根本原因,对水泵的频率响应和运行挠度进行了分析。分析的固有频率接近运行速度,这意味着由共振引起的高振动。由共振引起的振动的校正需要改变系统的弹簧刚度或质量来使泵变硬或变弱。本文通过设计变更对冷凝水泵减振进行了案例研究。安装泵后,通过测试验证结果。结果。