The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. The environmental protection progress and technology modernization caused a significant decrease of dust and gas emission at a nearby copper smelting plant. As a result, the pollution severity of the area changed from pollution level Ⅳ (very heavy) in 1980s to pollution level Ⅰ (light) after 2000. The flashover voltage was measured on porcelain post insulators under natural conditions in 1987 and, after insulator wetting with a water spray, in 2002-2004. The electrical strength of porcelain insulators was compared with insulators coated with a silicone rubber layer and with insulators coated by fluorourethane layer StaClean. The aging of insulator glazes and corrosion flanges are described. The external and internal charge records and temperature on metal oxide surge arresters with porcelain housing are also presented.
机译:本文报道了1981年至2004年Glogow试验站不同绝缘子和避雷器的污染性能。环境保护的进步和技术的现代化使附近铜冶炼厂的粉尘和气体排放量大大减少。结果,该地区的污染严重程度从1980年代的Ⅳ级(非常重)变为2000年以后的Ⅰ级(轻)。1987年在自然条件下以及绝缘子浸湿后在瓷柱绝缘子上测量了飞弧电压。在2002年至2004年间进行喷水。将瓷绝缘子的电气强度与涂有硅橡胶层的绝缘子和涂有氟尿烷层StaClean的绝缘子进行了比较。描述了绝缘子釉和腐蚀法兰的老化情况。还提供了带有瓷质外壳的金属氧化物电涌放电器的外部和内部电荷记录以及温度。