Metal oxide surge arresters (MOSA) are widely used as protective devices against switching and lightning over-voltages in electrical power systems. Appropriate modeling of their dynamic characteristics is very important for insulation coordination, arrester location and energy absorption studies. Working group 3.4.11 of IEEE has recommended a model that can be used in the range of current surge wave front time 0.5 to 45 μsec. This model has developed mainly for Substation class Surge arresters. In this paper the model applied for a distribution class arrester and validity of accuracy has compared with laboratory test results.
机译:金属氧化物电涌放电器(MOSA)被广泛用作电力系统中防止开关和雷电过电压的保护装置。对它们的动态特性进行适当的建模对于绝缘配合,避雷器位置和能量吸收研究非常重要。 IEEE工作组3.4.11建议使用可在电流浪涌波前时间0.5到45μsec范围内使用的模型。该模型主要针对变电站类电涌放电器而开发。本文将该模型应用于配电级避雷器,并将其准确性与实验室测试结果进行了比较。