The Study of Unitive Temperature Correcting Equation for Pressure—Measuring Copper Cylinders

机译:测压铜缸统一温度校正方程的研究

获取原文
获取原文并翻译 | 示例

摘要

In this paper, authors briefly analyzed reasons that the variation of working environment temperature will cause measurement error when pressure-measuring copper cylinders are used to measure dynamic pressure. To study the temperature error law of copper cylinders, Authors conducted for three batches of Φ3.5x8.75 copper cylinders; analyzed the variation law of pressure-measuring at high and low temperature based on the quasi-dynamic data; clarified the significance of deriving unitive temperature correcting formula for pressure-measuring copper cylinders, discussed the means of forming the unitive temperature correcting formula and derived the correcting formula by means of regression analysis .The feasibility of this equation has been tested and its result is satisfactory.
机译:在本文中,作者简要分析了使用测压铜筒测量动压时工作环境温度变化会引起测量误差的原因。为了研究铜筒的温度误差规律,作者对三批Φ3.5x8.75铜筒进行了研究。根据准动态数据,分析了高温和低温下压力测量的变化规律。阐明了推导统一温度校正公式对测压铜筒的意义,讨论了统一温度校正公式的形成方法,并通过回归分析推导了该校正公式。对该方程的可行性进行了测试,结果令人满意。 。