Element-free method (EFM) is used in this paper. Based on the chamber structure of 126kV self-energy SF_6 circuit breaker, the chamber electric field of 126kV self-energy SF_6 circuit breaker is analyzed and computed. By the analysis of calculation results, the insulation structure and size of 126kV self-energy SF_6 circuit breaker is confirmed. It explains some theoretic basis about electric field distribution for integer design of 126kV self-energy SF_6 circuit breaker.
机译:本文使用无元素方法(EFM)。基于126kV自能SF_6断路器的腔室结构,分析计算了126kV自能SF_6断路器的腔室电场。通过对计算结果的分析,确定了126kV自备能量SF_6断路器的绝缘结构和尺寸。阐述了126kV自能SF_6断路器整型设计的电场分布的理论基础。