The limitations for lightning impulse testing according to the IEC 60060-1 standard in regards of rise time and overshoot are identified and discussed. The different load range extension methods for lightning impulse testing with impulse voltage generators are introduced, their pros and cons are discussed and underlined by examples. Possible limitations for power transformer testing are explained. The impact of the revised lightning impulse evaluation, based on the revised IEC 60060-1, on the load range extension efficiency is shown.
机译:确定并讨论了根据IEC 60060-1标准的雷电冲击测试在上升时间和过冲方面的限制。介绍了使用脉冲电压发生器进行雷电脉冲测试的不同负载范围扩展方法,并通过实例讨论了它们的优缺点。解释了电源变压器测试的可能限制。显示了基于修订的IEC 60060-1的修订的雷电冲击评估对负载范围扩展效率的影响。