首页> 外文会议>International Symposium on High Voltage Engineering; 20050825-29; Beijing(CN) >Sensitivity Improvement of UHF PD Detection in GIS by Sensors Installed from CT Outlet Port
【24h】

Sensitivity Improvement of UHF PD Detection in GIS by Sensors Installed from CT Outlet Port

机译:通过CT出口端口安装的传感器提高GIS中UHF PD检测的灵敏度

获取原文
获取原文并翻译 | 示例

摘要

In the past, we usually detected the PD in GIS from the plate insulator outside of GIS by UHF antenna. The detecting sensitivity from the plate insulator outside of GIS is lower than that from the internal sensors in GIS. Recently we found that the sensor installation from CT outlet port will improve the sensitivity of PD detection in GIS markedly. In this paper, not only simulation and test in laboratory but also installation and test on site is discussed.
机译:过去,我们通常通过UHF天线从GIS外部的平板绝缘子检测GIS中的PD。 GIS外部板绝缘子的检测灵敏度低于GIS内部传感器的检测灵敏度。最近,我们发现从CT出口安装传感器将显着提高GIS中PD检测的灵敏度。本文不仅讨论了实验室的仿真和测试,而且还讨论了现场安装和测试。