The behaviour of Epoxy-Mica Insulators under different stresses was determined by the measurement of the loss factor, but the experiences have shown that this is not enough to make some conclusions concerning the long time behaviour of the insulation systems. Therefore further investigations were made on Epoxy-Mica insulation systems under AC stress of different frequencies including sensitive PD measurements during the electrical ageing process of stator bars for 10 kV machines. In the context of those experiments diverse time patterns were selected for the purpose of the observation of possible changes into the insulation. The PD behaviour as well as the derivated quantities were recorded in order to get sensible parameter for the evaluation of the ageing of the material. The results of these experiments show, that despite of the exposure to multiple electrical stresses the insulation capability is less affected by the electrical stress than by the thermal or mechanical stress. However the deterioration that caused by electrical stress could be used in order to determine the endurance of the insulation's capability.
机译:通过测量损耗因数可以确定环氧云母绝缘子在不同应力下的性能,但经验表明,这不足以得出有关绝缘系统长期性能的结论。因此,在不同频率的交流应力下对环氧云母绝缘系统进行了进一步的研究,包括在10 kV机器的定子棒的电老化过程中进行敏感的局部放电测量。在那些实验的背景下,为了观察绝缘可能的变化,选择了不同的时间模式。记录PD行为以及推导的量,以便获得用于评估材料老化的合理参数。这些实验的结果表明,尽管承受多种电应力,绝缘能力受电应力的影响比受热或机械应力的影响要小。但是,可以使用由电应力引起的劣化来确定绝缘能力的持久性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号