Chaira Underground Pumped Storage Power Station is located in the area of the Chaira Resort, approximately 100 km south-east of Sofia, Bulgaria. Waste heat is released by the water cooling system for transformer oil. Cooling water for transformers oil coolers enters the heat pump evaporator through the heat exchanger and buffer tanks. Hot water from the condenser will be delivered by circulation pumps to the accumulator and to the District Heating System. In order to save electric energy the heat pump will be operated predominantly during the night hours and heat will be accumulated in an accumulator made for this purpose with a storage capacity of 1500 m~3. This feasibility study will present brief technical and economical evaluations of the alternative heat sources energy efficiency.
机译:Chaira地下抽水蓄能电站位于Chaira Resort区域,在保加利亚索非亚东南约100公里处。废热由变压器油的水冷却系统释放。变压器油冷却器的冷却水通过热交换器和缓冲罐进入热泵蒸发器。来自冷凝器的热水将通过循环泵输送到蓄能器和区域供热系统。为了节省电能,热泵将主要在夜间运行,并且热量将蓄积在为此目的而制成的蓄能器中,蓄能器容量为1500 m〜3。这项可行性研究将对替代热源的能源效率进行简要的技术和经济评估。