【24h】

Venturi-Tube Performance In Wet Gas Using Different

机译:使用不同的湿气中的文丘里管性能

获取原文
获取原文并翻译 | 示例

摘要

Three 4-inch Venturi tubes have been tested in the NEL wet-gas test facility using three gas-liquid combinations: nitrogen-kerosene, argon-kerosene and nitrogen-water. Two gas-liquid density ratios were used for the tests with a gas densimetric Froude number range of 1.5 to 4.5, and a Lockhart-Martinelli parameter range of 0 to 0.3.rnThe alternative gas tests indicated a very small effect on the Venturi-tube performance, especially for the Venturi tube with convergent angle 10.5°. Using an alternative liquid, however, indicated a change in performance significant enough to produce large errors if not accounted for in a practical installation.rnFitting the experimental data obtained during the test programme using the Chisholm/de Leeuw model produced less than optimal Venturi-tube over-reading predictions, with relative errors in the range -4% to +3%. Consequently a modified model was developed which improved the representation of the experimental data to within ± 2% for more than 95% of test data points.
机译:已在NEL湿气测试设备中使用三种气液组合对三根4英寸的文丘里管进行了测试:氮-煤油,氩-煤油和氮-水。使用两种气液密度比进行测试,气体密度Froude数范围为1.5至4.5,Lockhart-Martinelli参数范围为0至0.3.rn替代气体测试表明对文丘里管性能的影响很小,尤其是对于收敛角为10.5°的文丘里管。但是,如果使用其他液体,则表明性能变化显着,即使在实际安装中未考虑到,也足以产生较大的误差。rn使用Chisholm / de Leeuw模型拟合测试程序期间获得的实验数据时,其产生的文丘里管不足最佳过度阅读预测,相对误差在-4%至+ 3%范围内。因此,开发了修改后的模型,该模型将超过95%的测试数据点的实验数据表示提高到±2%以内。