In order to improve the fault ride-though (FRT) capability of PMSG-based wind turbine generation system, an energy storage system composed of ultracapacitor (UC) and bidirectional Buck-Boost converter (BDBBC) paralleled to the DC-link of the dual PWM converter is used in this paper. The integrated control strategy for both grid-side converter (GSC) and BDBBC has been presented, which has two working modes. Under normal grid operation, it works in normal mode where the grid voltage orientation control (VOC) for gird-side converter and power control for BDBBC are applied. During the grid failures, it automatically switches to mode fault, where power control for GSC and voltage control for BDBBC are developed. Simulation results in MATLAB/SIMULINK verified the correctness and feasibility of the integrated control strategy.
机译:为了提高基于PMSG的风力涡轮机发电系统的故障穿越能力(FRT),由超级电容器(UC)和双向降压-升压转换器(BDBBC)组成的储能系统与双链DC链路并联本文使用PWM转换器。提出了电网侧变流器(GSC)和BDBBC的集成控制策略,具有两种工作模式。在正常电网运行下,它在正常模式下工作,其中应用了电网侧变流器的电网电压方向控制(VOC)和BDBBC的功率控制。在电网故障期间,它会自动切换到模式故障,从而开发用于GSC的电源控制和用于BDBBC的电压控制。 MATLAB / SIMULINK中的仿真结果验证了集成控制策略的正确性和可行性。