首页> 外文会议>International Conference on Renewable Power Generation >LVRT control strategy for photovoltaic inverter based on current derating
【24h】

LVRT control strategy for photovoltaic inverter based on current derating

机译:基于电流降额的光伏逆变器LVRT控制策略

获取原文
获取原文并翻译 | 示例

摘要

According to grid connected standard for photovoltaic power generation system, a LVRT control strategy for photovoltaic inverter based on active current derating is proposed. First, under grid normal condition a control strategy based on antiwindup PI controller is proposed, which reduces the influence of integral saturation on current reference value; Then, a LVRT control strategy based on current reference value derating in order to reduce DC bus voltage fluctuation and smooth grid-connected current change. Finally, LVRT experiment test results on a 500kVA photovoltaic inverter shows that the LVRT control strategy can apply various grid voltage dips and achieve good dynamic, static performance, the control parameters is universal with the control strategy under grid normal condition , and the switching logic of these two control strategy under grid normal and fault condition is simple.
机译:根据光伏发电系统并网标准,提出了基于有功电流降额的光伏逆变器LVRT控制策略。首先,在电网正常状态下,提出了一种基于抗饱和PI控制器的控制策略,减少了积分饱和对电流参考值的影响。然后,基于电流参考值降额的LVRT控制策略,以减少DC总线电压波动和平滑并网电流变化。最后,在500kVA光伏逆变器上的LVRT实验测试结果表明,LVRT控制策略可以应用各种电网电压突降并实现良好的动态,静态性能,控制参数与电网正常条件下的控制策略通用,并且开关逻辑为这两种控制策略在电网正常和故障情况下都很简单。