Living PSA program for NPP Dukovany, a four unit 440 MWe VVER 440 type NPP in Czech Republic, has been established as a framework for all activities related to risk assessment and risk based decision-making support in NPP Dukovany. This project is maintained in Nuclear Research Institute (NRI) in Rez near Prague, Czech Republic. Continuously updated PSA model has been extensively used both for development and for evaluation of NPP Dukovany symptom-based Emergency Operating Procedures (EOPs). The paper focuses on the process, how PSA for NPP Dukovany affected development and implementation of symptom-based EOPs in NPP Dukovany. The important insights and conclusions, which were obtained from EOPs pre-evaluation by PSA model and from EOPs incorporation into living PSA model, are discussed as well.
机译:NPP Dukovany的生活PSA计划是捷克共和国的一个四单元440 MWe VVER 440型NPP,已作为NPP Dukovany中与风险评估和基于风险的决策支持相关的所有活动的框架而建立。该项目由捷克共和国布拉格附近雷兹的核研究所(NRI)维护。不断更新的PSA模型已广泛用于开发和评估基于NPP Dukovany症状的紧急操作程序(EOP)。本文着重于过程,针对NPP Dukovany的PSA如何影响NPP Dukovany中基于症状的EOP的开发和实施。还讨论了重要的见解和结论,这些见解和结论是通过PSA模型对EOPs进行预评估以及将EOPs集成到活动PSA模型中获得的。