首页> 外文会议>International Conference on Power Transmission amp; Distribution Technology; 20051011-15; >A Drawback and Its Solutions of Automatic Closing Emergency Source Devices
【24h】

A Drawback and Its Solutions of Automatic Closing Emergency Source Devices

机译:自动关闭应急源设备的缺点及其解决方案

获取原文
获取原文并翻译 | 示例

摘要

This paper analyses a drawback of automatic closing emergency source devices. The fault is that the automatic closing emergency source device are not able to distinguish whether the line or the bus-bar faults, which cause the drawback of outage of bus-bar. The paper also gives the solution of distinguishing bus-bar or line faults by analyzing whether the current value of the working inlet power is higher than its nominal value before outage of bus-bar.
机译:本文分析了自动关闭应急源设备的缺点。故障在于自动关闭应急源设备无法区分是线路故障还是母线故障,从而导致母线故障。本文还通过分析工作入口功率的当前值是否高于母线中断之前的标称值,提供了区分母线或线路故障的解决方案。