首页> 外文会议>International conference on fuidization: New horizons in fluidization engineering; 20070513-18; Agassiz(CA) >SCALE-UP EFFECT ON HEAT TRANSFER IN FLUIDIZED BEDS NEAR THE ONSET OF TURBULENT FLUIDIZATION
【24h】

SCALE-UP EFFECT ON HEAT TRANSFER IN FLUIDIZED BEDS NEAR THE ONSET OF TURBULENT FLUIDIZATION

机译:湍流流化开始前流化床中传热的放大效应

获取原文
获取原文并翻译 | 示例

摘要

Heat transfer coefficients were measured in 0.29 m ID and 1.56 m ID fluidization columns with the same heater tube, identical alumina particles and geometrically scaled distributors. The maximum coefficients occurred in the turbulent fluidization flow regime. The Froude number based on superficial velocity and column diameter captures the scale-up effect well, so long as the heater is located in a region of similar flow structure.
机译:在具有相同加热管,相同氧化铝颗粒和几何比例分布器的0.29 m ID和1.56 m ID流化塔中测量了传热系数。最大系数出现在湍流流态中。只要加热器位于相似流动结构的区域中,基于表面速度和柱直径的弗洛德数就可以很好地捕获放大效应。