【24h】

Ring Artifact Correction for Industrial CT Images

机译:工业CT图像的环形伪像校正

获取原文
获取原文并翻译 | 示例

摘要

Response non-uniformity of detector elements causes ring artifacts on CT image. Based on "concentricity" character of ring artifacts, the method for correcting these artifacts is presented. In this method, the original CT image is transformed into polar coordinates, then average all rows of the transform result, extract high frequency parts from the average, and revise the result according to the high frequency parts, finally convert the revised result back into Cartesian coordinate to get the corrected CT image. Testifying the method uses the projection data collected with LDA-1024 linear diode array. Experimental results show the method can effectively reduce the ring artifacts. It improves industrial CT image quality.
机译:检测器元件的响应不均匀会导致CT图像上出现环形伪影。基于环形伪影的“同心度”特征,提出了矫正这些伪影的方法。该方法将原始CT图像转换为极坐标,然后对转换结果的所有行求平均,从平均值中提取高频部分,并根据高频部分修改结果,最后将修改后的结果转换回笛卡尔坐标系坐标以获取校正后的CT图像。为了验证该方法,使用了LDA-1024线性二极管阵列收集的投影数据。实验结果表明,该方法可以有效减少振铃伪影。它提高了工业CT图像质量。