首页> 外文会议>International Conference on Dam Safety Management(2008水库大坝安全管理国际研讨会) >Safety Inspection and Evaluation Analysis on Spillway Gate of Maodong Reservoir
【24h】

Safety Inspection and Evaluation Analysis on Spillway Gate of Maodong Reservoir

机译:茅洞水库溢洪道闸门安全检查与评价分析。

获取原文

摘要

Spillway gate of Maodong reservoir was built in the 1960s, Because of the limiting of technical and economic conditions at that time, the engineering existed many problems in the design, construction and materials. The spillway gate operated fourty years, it hasn't been repaired thoroughly, overall construction is aging, engineering disease phenomenon is outstanding, these effect safety operation of Maodong reservoir. Based on the literature stud-ies and understanding present situation of engineering management, This paper makes a com-prehensive field safety inspection, and check calculation Referring to the relevant design specification on the spillway gate, and carries out a synthetic analysis with the present prob-lem in the structure. On the basis of the Guidelines for Dam Safety Evaluation and Rules for Safety Appraisal of Sluices, the author gives Safety Evaluation. The results show that secur-ity level of the spillway gate is belong to C-class, and that the spillway gate should be strengthened as early as possible to assure its safe operation.
机译:茅洞水库泄洪闸门始建于1960年代,由于当时的技术和经济条件的限制,工程在设计,施工和材料上存在许多问题。溢洪道闸门运行了40年,尚未彻底修复,整体施工老化,工程病现象突出,这些都影响了茅洞水库的安全运行。基于文献研究和对工程管理现状的了解,本文结合溢洪道闸门的有关设计规范,进行了全面的现场安全检查和核算计算,并结合现今的问题进行了综合分析。 -lem结构。根据《大坝安全评估指南》和《水闸安全评估规则》,作者进行了安全评估。结果表明,溢洪道闸门的安全等级为C级,应尽早加强溢洪道闸门的安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号