CASE STUDY: REPAIR OF A 12-YEAR OLD PRECAST CONCRETE FACADE

机译:案例研究:修复12年的预制混凝土幕墙

获取原文
获取原文并翻译 | 示例

摘要

It is the authors' intent to demonstrate the variety of issues to be considered and the proper repair techniques to be implemented on a precast concrete facade that suffered from a variety of afflictions. The facade repairs for the subject building addressed design and construction deficiencies including panel cracking, corrosion related distress at anchorages, and installation of supplemental panel fixings (supports) to resist hurricane-force wind loads. This paper also describes the selection of joint sealant and a unique two component clear water repellent system, which was used to preclude further streaking and eventual etching of the glass surfaces. Lessons learned from this case history could be used to establish general guidelines for evaluation, repair and protection of facades of similar type.
机译:作者的目的是演示要考虑的各种问题以及在遭受各种折磨的预制混凝土外墙上实施适当的修复技术。针对主题建筑的外墙维修解决了设计和施工方面的缺陷,包括面板开裂,锚固处的腐蚀相关窘迫以及安装补充面板固定装置(支撑)以抵抗飓风的风荷载。本文还描述了接缝密封剂的选择以及独特的两组分透明防水系统,该系统用于防止进一步划痕和最终蚀刻玻璃表面。从该案例历史中学到的经验教训可用于建立评估,修复和保护类似类型外墙的一般准则。