This paper presents the achievement of a China NSFC project. The Laser Tracker System (LTS) is a portable 3D large size measuring system. The measuring conditions such as time and temperature can greatly affect the measuring accuracy of LTS. This paper pays a great attention to study how the time and temperature affect the measuring accuracy of LTS. Coordinate Measuring Machine (CMM) is employed as a high-level measuring instrument to validate LTS. The experiments have been done to find how the time and temperature affect the measuring accuracy of LTS. The experiments show the LTS can work well with the highest measuring accuracy just after three-hour warm-up. However, the LTS becomes unstable and the measuring accuracy decreases after 10 hours. The LTS needs calibration and compensation every 10 hours. The experiments show that the measuring error can be up to 29.6μm when the measuring temperature is 30.5℃ even if the measuring error is less than 5.9μm while the temperature is between 20℃ and 23.8℃. The research provides a very useful guidance for application of LTS.
机译:本文介绍了中国国家自然科学基金项目的成果。激光跟踪仪系统(LTS)是便携式3D大型测量系统。时间和温度等测量条件会极大地影响LTS的测量精度。本文非常关注研究时间和温度如何影响LTS的测量精度。坐标测量机(CMM)被用作验证LTS的高级测量仪器。已经进行了实验以发现时间和温度如何影响LTS的测量精度。实验表明,LTS在预热三小时后即可以最高的测量精度很好地工作。但是,LTS变得不稳定,并且10小时后测量精度会降低。 LTS每10小时需要校准和补偿。实验表明,在温度为30.5℃时,即使温度在20℃至23.8℃之间,测量误差小于5.9μm,测量误差仍可达到29.6μm。该研究为LTS的应用提供了非常有用的指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号