Steep-front impulse voltage test is one of the main methods to evaluate the quality of cap and pin insulators. However, there is no standard steep-front impulse wave source to calibrate steep-front impulse voltage of the measurement system. The standard lightning impulse voltage is usually used to as calibration wave source. In this paper, three resistance dividers of steep-front impulse voltage measurement system are calibrated by standard lightning wave source. It was found that the ratio variety of divider is less than 3% which meets the standard. However, two resistance dividers parallel measurement of the same steep-front voltage signal still produce a measurement error of magnitude of 10%. The error source is analyzed in the paper which revealed that the square-wave response of the divider will have a large impact on the measurement error of the steep-front voltage, but have little effect on the lightning impulse voltage. Therefore, using a standard lightning voltage source to calibrate the resistance divider of the steep-front impulse measurement system will result in greater error. Finally, the mathematical method of error correction is proposed, and the measurement error caused by the square wave response can be reduced by the deconvolution calculation.
机译:陡前脉冲电压测试是评估帽形和针形绝缘子质量的主要方法之一。但是,没有标准的陡峭前冲激波源来校准测量系统的陡峭前冲激波电压。标准雷电冲击电压通常用作校准波源。本文采用标准的雷电波源校准了陡前脉冲电压测量系统的三个电阻分压器。发现分频器的比例变化小于3%,符合标准。但是,两个电阻分压器并行测量相同的陡峭前电压信号仍然会产生10%的测量误差。本文分析了误差源,发现分压器的方波响应将对陡峭前沿电压的测量误差产生较大影响,而对雷电冲击电压的影响很小。因此,使用标准的雷电电压源校准陡峭前冲测量系统的电阻分压器会导致更大的误差。最后提出了误差校正的数学方法,通过反卷积计算可以减小由方波响应引起的测量误差。

著录项

  • 来源
  • 会议地点 Budapest(HU)
  • 作者单位

    State Key Laboratory of Control and Simulation of Power System and Generation Equipment Department of Electrical Engineering Tsinghua University Beijing 100084 China Department of High Voltage China Electrical Power Research Institute Beijing 100192 China;

    State Key Laboratory of Control and Simulation of Power System and Generation Equipment Department of Electrical Engineering Tsinghua University Beijing 100084 China;

    Department of High Voltage China Electrical Power Research Institute Beijing 100192 China;

  • 会议组织
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

    Steep-front impulse voltage test; Resistance divider; Calibration; Error;

    机译:陡前脉冲电压测试;电阻分压器;校准;错误;