By means of electrochemical impedance spectroscopy (EIS) technique, the electrochemical behavior offusion bonded epoxy coating (FBEC) with linear defects/X70 steel system in 3.5%NaCl solution wasstudied. The defects were made at right angles to form a 20mm×20mm cross, and the test involvedscribing the sample through the paint down to the bare metal. The experimental results showed thatcorrosion process can be divided into three stages. In the initial stage of eroding,the electrochemicalbehavior of this system is similar to bare steel. In the interim stage, corrosion products accumulate inthe interior of linear defects. It makes pH of solution in the interior of linear defects fall down andcauses the rupture of coating bonded joint. In the final stage of eroding, the EIS data show that alongthe seams,the FBE coating peels off steel substrate. EIS data had been interpreted and discussed interms of the time dependence of the electrical (paint coating) and electrochemical (steel substrate)parameters. The parameters are associated with interfacial processes describing carbon steel/the fusionbonded epoxy coating with linear defects system deterioration.
机译:利用电化学阻抗谱(EIS)技术,研究了在3.5%NaCl溶液中具有线性缺陷/ X70钢体系的熔凝环氧涂层(FBEC)的电化学行为。缺陷以直角进行加工以形成20mm×20mm的十字,并且该测试涉及将样品划过油漆直至裸金属。实验结果表明,腐蚀过程可分为三个阶段。在腐蚀的初始阶段,该系统的电化学行为类似于裸钢。在过渡阶段,腐蚀产物会堆积在线性缺陷的内部。这会导致线性缺陷内部溶液的pH值下降,并导致涂层结合点断裂。在腐蚀的最后阶段,EIS数据表明,沿着接缝,FBE涂层会从钢基材上剥落。 EIS数据已根据电参数(涂料)和电化学参数(钢基材)的时间依赖性进行了解释和讨论。这些参数与描述碳钢/具有线性缺陷系统恶化的熔融粘合环氧涂料的界面工艺有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号