In this paper,based on the field-frequency lock technology commonly used in the current commercial nuclear magnetic resonance spectrometers to maintain the magnetic field homogeneity and the theory of weak signal detection,a lock preamplifier at the front-end of lock channel is designed and implemented. The preamplifier consists of broadband amplifier,RF switch and attenuation circuits. In the 20-200 MHz the fabricated preamplifier exhibits a gain of 53 dB and in-bandfluctuation of I dB. The whole noise figure of receiving channel is about 1.5 dB. The delay of RF switch is less than 220 ns. For the transmitter channel the total attenuation range is 30 dB with a 2.0 dB minimum step size. Compared with the lock preamplifier of the commercial spectrometers,the developed preamplifier shows a lower noise figure,a smaller in-band fluctuation and a shorter delay of the switch. Therefore the preamplifier can be applied to nuclear magnetic resonance spectrometers from 200 MHz to 900 MHz.
机译:本文基于目前商用核磁共振波谱仪常用的场频锁定技术来保持磁场的均匀性和弱信号检测的原理,设计了锁定通道前端的锁定前置放大器,已实施。前置放大器由宽带放大器,射频开关和衰减电路组成。在20-200 MHz中,预制的前置放大器的增益为53 dB,带内波动为1 dB。接收通道的整个噪声系数约为1.5 dB。 RF开关的延迟小于220 ns。对于发射器通道,总衰减范围为30 dB,最小步长为2.0 dB。与商用频谱仪的锁定前置放大器相比,开发的前置放大器具有更低的噪声系数,更小的带内波动和更短的切换延迟。因此,该前置放大器可应用于200 MHz至900 MHz的核磁共振谱仪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号