It is impossible to eliminate all occurrences of sparking andnlocalized heating from the interior of electric machines during the 20nto 40 years that they are normally in service. One can minimize thenprobability of sparking and localized heating by exercising precautionsnwhich will eliminate or minimize the sources of these conditions in ACnmachines. Most new machines have a low probability of sparking but somendesign steps can be taken which condition the machine as a sparking typenor a nonsparking type. The paper discusses the aspects of arcing betweennrotor and stator in the air gap, sparking between rotor parts, sparkingnbetween frame components, sparking due to broken or open bars and endnrings and surface discharge on the stator winding. Also discussed isnwhat action, if any, can be taken in design, application and maintenancento eliminate or control these sparking problems
机译:在正常使用的20至40年间,不可能消除电机内部出现的所有火花和局部发热。通过采取预防措施,可以最大程度地减少火花和局部加热的可能性,这将消除或最小化ACn机器中这些情况的根源。大多数新机器发生火花的可能性很小,但是可以采取一些设计步骤,将机器作为火花类型或非火花类型。本文讨论了气隙中转子与定子之间的电弧,转子部件之间的火花,框架部件之间的火花,由于断开或打开的杆和端环造成的火花以及定子绕组上的表面放电的方面。还讨论了在设计,应用和维护中是否采取了任何措施以消除或控制这些火花问题