Pulsed thermography is a technique in which pulsed flash energy is applied to the surface and the temperature of the surface is recorded and analysed. Generally the temperature above the defect areas is different from that of the surrounding area. However, when the surface of the specimen is highly reflective, artifact of fixed pattern could be introduced which comes from the reflection of the heated lamp tube. Several methods were used to eliminate the artifact, including spatial filtering, image subtraction and frequency domain filtering. Results show that spatial filtering may be the best method of the fixed pattern artifact elimination.
机译:脉冲热成像技术是将脉冲闪光能量施加到表面并记录和分析表面温度的技术。通常,缺陷区域上方的温度与周围区域的温度不同。但是,当样品的表面具有高反射性时,由于加热的灯管的反射会引入固定图案的假象。几种方法用于消除伪影,包括空间滤波,图像减法和频域滤波。结果表明,空间滤波可能是消除固定模式伪影的最佳方法。