首页> 外文会议>Infrared imaging systems: Design, analysis, modeling, and testing XX >Improving MTF measurements of under-sampled optical systems
【24h】

Improving MTF measurements of under-sampled optical systems

机译:改善欠采样光学系统的MTF测量

获取原文
获取原文并翻译 | 示例

摘要

The modulation transfer function (MTF) of optical systems is often derived by taking the Fourier transform (FT) of a measured line spread function. Recently, methods of performing Fourier transforms that are common in infrared spectroscopy have been applied to MTF calculations. Proper apodization and phase correction have been shown to improve MTF calculations in optical systems. In this paper these methods as well as another filtering algorithm based on phase are applied to under-sampled optical systems. Results, both with and without the additional processing are presented and the differences are discussed.
机译:光学系统的调制传递函数(MTF)通常是通过对测得的线扩展函数进行傅立叶变换(FT)得出的。近来,执行红外光谱中常见的傅立叶变换的方法已经应用于MTF计算。适当的切趾和相位校正已被证明可以改善光学系统中的MTF计算。本文将这些方法以及另一种基于相位的滤波算法应用于欠采样光学系统。给出了有无附加处理的结果,并讨论了差异。