This study attempts to investigate the present indoor air quality (IAQ) of the four hot spring hotels in Guangdong,China. Air pollutants measured in this study including radon (222Rn), respirable suspended particulate matter (PM10 and PM2s), carbon monoxide (CO) and carbon dioxide (CO2). The results indicate that the 24-h average levels of CO2 and PM10 in the hotel rooms investigated were 89% and 67% higher than the present IAQ standard of China. CO2 and PM10 levels were usually higher indoors than outdoors because of the tourists' activities and insufficient ventilation. When there was hot spring water bathing in the baths, average radon levels were 144%~416% higher in the hotel rooms and 451%~1172% higher in the baths compared to the corresponding average levels when there was no spring water use. The indoor radon concentrations were related to radonconcentration in spring water and the bathing time.
机译:本研究试图调查中国广东省四家温泉酒店的室内空气质量(IAQ)。在这项研究中测量的空气污染物包括ra(222Rn),可吸入悬浮颗粒物(PM10和PM2s),一氧化碳(CO)和二氧化碳(CO2)。结果表明,所调查酒店客房的24小时平均CO2和PM10水平比中国现行的室内空气质量标准高89%和67%。由于游客的活动和通风不足,室内的CO2和PM10水平通常高于室外。与没有泉水使用的相应平均水平相比,在温泉浴中使用温泉水时,酒店客房的平均ra水平高出144%〜416%,在浴室中平均高451%〜1172%。室内ra浓度与泉水中water浓度和沐浴时间有关。