首页> 外文会议>IEEE Photovoltaic Specialist Conference >Performance of Field-Aged PV Modules in India: Results from 2016 All India Survey of PV Module Reliability
【24h】

Performance of Field-Aged PV Modules in India: Results from 2016 All India Survey of PV Module Reliability

机译:印度现场老化光伏组件的性能:2016年全印度光伏组件可靠性调查的结果

获取原文

摘要

All India Survey of Photovoltaic Module Reliability conducted in 2016, in which a total of 925 modules were inspected in different climatic zones of India. The average degradation rate of the Group A (`All' sites) modules is 1.23%/year and the so-called `Good' sites is 0.63%/year, better than that observed in the 2014 Survey, the reason being partly the inclusion of more large PV power plants, and also discounting of 2% LID in 2016 analysis methodology. The modules in `Hot' climates degrade faster than modules in `Non-Hot' climates, consistent with earlier results. Modules in small systems (capacity 100 kW). Roof-mounted systems also degrade at a faster rate than ground-mounted systems.
机译:印度于2016年进行了全印度光伏组件可靠性调查,其中对印度不同气候区的925个组件进行了检查。 A组(“所有”站点)模块的平均退化率是1.23%/年,所谓的“良好”站点是0.63%/年,好于2014年调查中观察到的原因,部分原因是更多大型光伏电站,以及在2016年分析方法中折现2%的LID。与较早的结果一致,“热”气候中的模块降级速度要快于“非热”气候中的模块降级速度。小型系统中的模块(容量100 kW)。屋顶安装系统的降级速度也比地面安装系统快。