首页> 外文会议>IEEE Photovoltaic Specialist Conference >Field Degradation and Failures of Aged Crystalline Silicon PV Modules in Mexico
【24h】

Field Degradation and Failures of Aged Crystalline Silicon PV Modules in Mexico

机译:墨西哥老化的晶体硅光伏组件的现场退化和故障

获取原文

摘要

This paper presents the visual defects and performance degradation rates of crystalline silicon photovoltaic (PV) modules exposed in two different climatic conditions (Hot-Humid and Temperate) of Mexico between 10 and 25 years. An extensive evaluation of these modules was performed using different visual, optical and electrical tools including 86-point visual inspection, electroluminescence imaging, infrared imaging, module-level visible-near IR reflectance and current-voltage measurements. The dominant visual defects were determined to be encapsulant discoloration, encapsulant delamination and cell metallization corrosion. The average annual power degradation rate was determined to be between 1.4% and 1.5% for all the modules surveyed.
机译:本文介绍了暴露在墨西哥的两种不同气候条件下(热湿润和温带)10至25年之间的晶体硅光伏(PV)组件的视觉缺陷和性能退化率。使用不同的视觉,光学和电气工具对这些模块进行了广泛的评估,包括86点视觉检查,电致发光成像,红外成像,模块级近红外反射率和电流电压测量。确定的主要视觉缺陷是密封剂变色,密封剂分层和电池金属化腐蚀。所有被调查模块的年平均功率退化率确定为1.4%至1.5%。