摘要

This paper presents an adaptive auto-reclosing protection scheme and fault position identification technique for three-terminal mixed line system using faulted section identification (FSI) information. The mixed line system is a power transmission network containing both overhead line (OHL) and underground cable (UGC). In this approach, FSI index is computed using the incident traveling wave (TW) arrival time measured at each terminal, length and wave speed of the section. Precise fault location (FL) can be computed using FSI and TW incident wave arrival time measured at each terminal. TWs are extracted from the current signal measured at each terminal using a notch filter and special sensors are not required. The technique is tested using PSCAD/EMTDC simulation tool and shows that the technique classifies the precise faulted section and locate the fault position. The proposed technique does not require tap point measurements and it saves the communication and sensor cost for practical applications.
机译:提出了一种利用故障区域识别(FSI)信息的三端混合线路系统自适应重合闸保护方案和故障位置识别技术。混合线路系统是同时包含架空线(OHL)和地下电缆(UGC)的输电网络。在这种方法中,使用在每个终端测量的入射行波(TW)到达时间,截面的长度和波速来计算FSI指数。可以使用在每个终端测量的FSI和TW入射波到达时间来计算精确的故障位置(FL)。使用陷波滤波器从每个端子测得的电流信号中提取TW,并且不需要特殊的传感器。使用PSCAD / EMTDC仿真工具对该技术进行了测试,结果表明该技术可以对精确的断层进行分类并确定故障位置。所提出的技术不需要分接点测量,并且为实际应用节省了通信和传感器成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号