This paper presents the comparisons between time-domain voltage and current measurement techniques for interference analysis in Power Line Communication (PLC) application. Voltage measurement is performed by directly sensing the mains voltage from a speed-controlled water pump using a 1:1000 voltage divider, whilst the current is measured using three types of sensors: current clamp, hall element, and differential probe over a shunt resistor. Voltage and current from these sensors are read with a digital oscilloscope. Impedance and power are calculated as well using post-processing software, in which the results can be analyzed in the frequency domain using a spectrogram to observe the possibility of performing communication. Voltage and current transducers should have transfer functions which are independent of frequency when performing time-domain measurements.
机译:本文介绍了用于电力线通信(PLC)应用中的干扰分析的时域电压和电流测量技术之间的比较。电压测量是通过使用1:1000分压器直接感测调速水泵的电源电压来进行的,而电流则使用三种类型的传感器进行测量:电流钳,霍尔元件和分流电阻上的差分探头。这些传感器的电压和电流通过数字示波器读取。使用后处理软件还可以计算阻抗和功率,其中可以使用频谱图在频域中分析结果,以观察进行通讯的可能性。电压和电流传感器在执行时域测量时应具有与频率无关的传递函数。