The calibration of the impulse current measurement system has been clearly stipulated in the standard GB/T 16927.4-2014, With the implementation of GB/T 16927.4-2014. In order to promote the standardization of the calibration system, this paper analyzes the impulse current measurement system architecture, Analysis of the impulse current measurement system scale factor calibration methods and the uncertainty calculation of time-parameter measurements. Then, each test example was executed. The uncertainty of under calibration impulse current measurement system was evaluation, For the implementation of standard provides the beneficial practice and guidance.
机译:随着GB / T 16927.4-2014的实施,脉冲电流测量系统的校准已在GB / T 16927.4-2014标准中明确规定。为了促进标定系统的标准化,本文分析了脉冲电流测量系统的体系结构,分析了脉冲电流测量系统的比例因子标定方法和时间参数测量的不确定度计算。然后,执行每个测试示例。对欠校准脉冲电流测量系统的不确定度进行了评估,为标准的实施提供了有益的实践和指导。