首页> 外文会议>IEEE International Conference on Compatibility, Power Electronics and Power Engineering >Dynamic Rating of Three-Core XLPE Submarine Cables Considering the Impact of Renewable Power Generation
【24h】

Dynamic Rating of Three-Core XLPE Submarine Cables Considering the Impact of Renewable Power Generation

机译:考虑可再生能源发电影响的三芯XLPE海底电缆的动态额定值

获取原文

摘要

This paper discusses how to determine the most suitable high voltage alternating current (HVAC) submarine cable in the design phase of new projects. A thermal ladder network method (LNM) is used to analyse the thermal behaviour in the centre of the conductor as the hottest spot of the cable. Based on an approved static cable rating method and thermal cable analysis of transient conditions, applied by a step function with transient time duration greater than one hour, this paper proposes a method for a dynamic rating of submarine cables. The dynamic rating accomplished through an iterative process. The method is tested with MATLAB simulation and validated in comparison to a finite element method (FEM) based approach with high accuracy.
机译:本文讨论了在新项目的设计阶段如何确定最合适的高压交流(HVAC)海底电缆。使用热梯形网络方法(LNM)分析作为电缆最热点的导体中心的热行为。基于经认可的静态电缆定额方法和瞬态条件的热电缆分析,并通过阶跃函数应用瞬态持续时间大于一小时,该方法提出了一种对海底电缆进行动态定额的方法。动态评级是通过迭代过程完成的。该方法已通过MATLAB仿真进行了测试,并与基于有限元方法(FEM)的方法进行了比较,并进行了高精度验证。