The technology shift from 1000-V to 1500-V DC voltage can reduce the installation cost of Photovoltaic (PV) systems to a large extent. However, the increased DC-link voltage also imposes a challenge to PV inverters, and thus, it requires careful consideration in the design phase and the control in operation. In this context, this paper evaluates the thermal performance of two-level and three-level 1500-VDC single-stage PV inverters under constant power generation (CPG) operation. A 160-kW PV system and its operating conditions have been defined for comparison. Three IGBT modules from a leading manufacturer have been selected for different inverter topologies. The thermal performance evaluation of the 1500-VDC PV inverters under CPG operation conditions has been carried out through PLECS modeling. This evaluation can be used for topology and component selection of 1500-VDC PV inverters and improving their operation with better thermal performance.
机译:从1000V直流电压到1500V直流电压的技术转移可以在很大程度上降低光伏(PV)系统的安装成本。然而,增加的直流母线电压也给PV逆变器带来了挑战,因此,在设计阶段和操作控制中需要仔细考虑。在这种情况下,本文评估了在恒定功率发电(CPG)操作下两级和三级1500-VDC单级PV逆变器的热性能。为了比较,定义了一个160千瓦的光伏系统及其运行条件。选择了三个领先制造商的IGBT模块用于不同的逆变器拓扑。通过PLECS模型对CPG运行条件下1500-VDC PV逆变器的热性能进行了评估。该评估可用于1500-VDC PV逆变器的拓扑和组件选择,并以更好的热性能改善其运行。