Typical methods for detecting traveling-wave arrival time such as Sliding discrete Fourier transform(SDFT) or discrete wavelet transform are unable to extract the arrival time of the steep pulse accurately. This paper proposes a new method using Short-time Matrix Pencil method to detect the traveling-wave arrival time of arc fault in Medium Voltage cables. Short-time Matrix Pencil method extracts sampling signals by a sliding time window. In each window, Matrix pencil decomposition is applied to the samples. The pulse of arc fault is in the middle of the window when the damping factors become zero. EMTP is used to build Medium Voltage cable arc fault simulation model to verify this method. The results show that the method proposed is able to accurately detect the arrival time of the pulse induced by the arc fault and effectively locate the arc fault at different positions.
机译:滑动离散傅里叶变换(SDFT)或离散小波变换等检测行波到达时间的典型方法无法准确提取陡脉冲的到达时间。提出了一种用短时矩阵笔法检测中压电缆电弧故障行波到达时间的新方法。短时矩阵笔方法通过滑动时间窗口提取采样信号。在每个窗口中,将矩阵铅笔分解应用于样本。当阻尼系数变为零时,电弧故障脉冲在窗口的中间。 EMTP用于建立中压电缆电弧故障仿真模型以验证该方法。结果表明,该方法能够准确检测出电弧故障引起的脉冲的到达时间,并有效地将电弧故障定位在不同的位置。