首页> 外文会议>IEEE Asia Power and Energy Engineering Conference >An Improved Variable-Frequency Series Resonant System for PD Detection of MV Power Cables Based on DAC Technology
【24h】

An Improved Variable-Frequency Series Resonant System for PD Detection of MV Power Cables Based on DAC Technology

机译:基于DAC技术的中压电力线局部放电的改进变频串联谐振系统。

获取原文

摘要

Medium voltage (MV) Power cables is gaining an important role in distribution power grids. However, potential defects and faults in the cables pose a great threat to the power system. Partial discharge (PD), which can reveal the potential defects and faults, is worldwide accepted as an indicator for insulation condition of MV power cables. Nowadays, the variable-frequency series resonant (ACRF) system can only be used for the withstand test, due to the disturbance produced by the inverter. Besides, the commercial damped AC system for PD detection is expensive because of the high voltage switches. This paper presents an improved ACRF system, which is a combination of the ACRF system and the damped AC (DAC) system. The system uses the ACRF method to excite high voltage on the test cables, and uses a relative low voltage bi-directional solid-state switch to obtain the pure DAC voltage. An implementation of the system was established for PD detection of a 200m faulty cable. The experimental results verify the feasibility of the system.
机译:中压(MV)电力电缆在配电网中正扮演着重要角色。然而,电缆中潜在的缺陷和故障对电力系统构成了极大的威胁。局部放电(PD)可以揭示潜在的缺陷和故障,已成为全世界公认的MV电力电缆绝缘状况的指标。如今,由于逆变器产生的干扰,变频串联谐振(ACRF)系统只能用于耐压测试。此外,由于高压开关,用于PD检测的商业阻尼AC系统昂贵。本文提出了一种改进的ACRF系统,它是ACRF系统和阻尼AC(DAC)系统的组合。该系统使用ACRF方法在测试电缆上激励高电压,并使用相对低电压的双向固态开关来获得纯DAC电压。建立了该系统的实现,以用于200m故障电缆的PD检测。实验结果验证了该系统的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号