Large suspension bridges are increasingly exposed to fire risks as the traffic carried by them increases. A truck fire on a suspension bridge may be a relatively likely accident that may lead to main cable failure or a strength reduction that will either cause down classification of the load carrying capacity or need for long lasting repairs of the main cable, all at high costs for society. To consider fire protection of suspension bridge cables is not yet standard practice but there is a need for systematically assessing the fire risks for the cables and implementing mitigation measures as needed for both new and existing bridges. In 2017, the New Little Belt Bridge in Denmark was retrofitted with passive fire protection for the main cables and in 2018, a similar retrofit of the Great Belt East Bridge in Denmark starts. The dimensions, design and configuration of the main cables are different for the two bridges. Special efforts were to model heat penetration into the main cable following a fire, and the resulting strength reduction. This paper describes the systematic process to evaluate and provide fire protection for the main cables of these bridges.
机译:随着大型悬索桥交通量的增加,它们越来越面临着火灾的危险。吊桥上的卡车起火可能是相对可能的事故,可能会导致主电缆故障或强度降低,从而导致承载能力下降,或者需要对主电缆进行长期维修,所有这些费用很高为社会。考虑吊桥电缆的防火还不是标准做法,但是有必要系统地评估电缆的火灾风险,并根据新桥和现有桥的需要采取缓解措施。 2017年,对丹麦的新小皮带桥进行了主电缆的被动防火保护改造,并于2018年开始了对丹麦大皮带东桥的类似改造。两个桥的主电缆的尺寸,设计和配置均不同。专门的工作是模拟火灾后热渗透到主电缆中的情况,并由此降低强度。本文介绍了评估这些桥梁的主要电缆并为其提供防火措施的系统过程。