首页> 外文会议>Hyperspectral remte sensing applications and environmental monitoring and safety testing technology >In-flight absolute radiometric calibration of MODIS using the irradiance-based method
【24h】

In-flight absolute radiometric calibration of MODIS using the irradiance-based method

机译:使用基于辐照度的方法进行MODIS的飞行中绝对辐射定标

获取原文
获取原文并翻译 | 示例

摘要

In order to reduce the calibration uncertainty of the reflectance-based method brought by the assumption of the aerosol model, the irradiance-based method, known as improved reflectance-based method, was proposed. The irradiance-based method is described in this paper. The radiometric calibration field campaign was performed at Dunhuang test site on 27 August, 2014. A hyperspectral irradiance meter (HSIM) developed by Anhui Institute of Optics and Fine Mechanics (AIOFM) was used to measure the diffuse-to-global spectral irradiance ratio. The irradiance-based method and the reflectance-based method were performed to calibrate the first four bands of Moderate Resolution Imaging Spectroradiometer (MODIS). The results of two methods were compared with result of MODIS on-board calibrator. The comparison shows that the result of irradiance-based method has a good consistency with on-board calibration and reflectance-based method results. The difference of calibration coefficients between irradiance-based and on-board method was less than 1.4%. Due to the limitations of the irradiance-based method, a clear sky and stable atmospheric condition is required for the entire half of the calibration day to provide the data necessary for the extrapolation of diffuse-to-global ratio in viewing direction. A study on the effects of aerosol mode assumption on the final apparent reflectance was performed on both the irradiance-based method and the reflectance-based method by selecting different aerosol modes to predict the apparent reflectance. The results show that aerosol mode assumption has a great effect on the reflectance-based method, however slight effect on the irradiance-based method.
机译:为了减少气溶胶模型假设带来的基于反射率的方法的校准不确定性,提出了一种基于辐照度的方法,称为改进的基于反射率的方法。本文介绍了基于辐照度的方法。 2014年8月27日在敦煌测试场进行了辐射校准现场活动。安徽省光学精密机械研究所(AIOFM)开发的高光谱辐照度仪(HSIM)用于测量散射光谱与全局光谱的辐照度比。进行了基于辐照度的方法和基于反射率的方法,以校准中分辨率成像光谱仪(MODIS)的前四个波段。将两种方法的结果与MODIS车载校准器的结果进行了比较。比较表明,基于辐照度的方法结果与车载校准和基于反射率的方法结果具有良好的一致性。基于辐照度的方法和车载方法之间的校准系数差异小于1.4%。由于基于辐照度的方法的局限性,在整个校准日的整个半天都需要晴朗的天空和稳定的大气条件,以提供在观察方向上外推至全局比例的必要数据。通过选择不同的气溶胶模式来预测表观反射率,对基于辐照度的方法和基于反射率的方法进行了气溶胶模式假设对最终表观反射率的影响的研究。结果表明,气溶胶模式假设对基于反射率的方法影响很大,而对基于辐照度的方法影响很小。

著录项

  • 来源
  • 会议地点 Beijing(CN)
  • 作者单位

    Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China,University of Science and Technology of China, Hefei 230026, China;

    Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China;

    Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China;

    Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China,University of Science and Technology of China, Hefei 230026, China;

    Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    radiometric calibration; irradiance-based method; diffuse-to-global ratio; MODIS;

    机译:辐射定标;基于辐照度的方法;扩散与全局比率;莫迪斯;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号