Fourier transform infrared spectrometry can be used for harmful gases online detection, Due to the overlap and mutual interference between the absorption spectra, accurate detection is very difficult for the mixture gas. In the wave number of 400~2200cm~(-1), the infrared absorption spectrum characteristics of typical harmful gases in underground closed environment were analyzed, the position of characteristic absorption peak was studied, and the infrared absorption frequency of each harmful gas was determined. The reasonable detection scheme was designed, and the mutual interference of the detection was eliminated. The harmful gases include SO_2, CO_2, H_2S, NH_3, NO_2, CO, O_3, H_2CO, C_6H_6 and H_2O.
机译:傅里叶变换红外光谱法可用于有害气体的在线检测,由于吸收光谱之间的重叠和相互干扰,对混合气体进行精确检测非常困难。在400〜2200cm〜(-1)的波数下,分析了地下封闭环境中典型有害气体的红外吸收光谱特征,研究了特征吸收峰的位置,确定了每种有害气体的红外吸收频率。设计了合理的检测方案,消除了检测的相互干扰。有害气体包括SO_2,CO_2,H_2S,NH_3,NO_2,CO,O_3,H_2CO,C_6H_6和H_2O。