The submitted paper deals withrncomparative PD studies on insulation defectsrnunder both, continuous and damped AC voltages.rnThe PD data of different failure types werernanalysed based on advanced digital PD signalrnprocessing. The test results reveal, that the PDrnbehaviour under both kinds of voltage stressesrnare well comparable for insulation defects in solidrndielectrics. Only for PD sources in pure air gapsrnlarger deviations have been found.
机译:提交的论文针对连续和阻尼交流电压下绝缘缺陷的PD对比研究。基于先进的数字PD信号处理,分析了不同故障类型的PD数据。测试结果表明,两种电压应力下的PDrn行为与固态电介质中的绝缘缺陷具有相当的可比性。仅对于纯净空气间隙中的PD源,发现较大的偏差。